Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 216: 120940, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32456901

RESUMO

Gadolinium-based contrast agents (GBCA) are widely used to enhance tissue contrast during magnetic resonance imaging (MRI) procedures. However, free Gadolinium (Gd) is undesirable as a drug substance, due to its high toxicity. Consequently, a coordinating ligand is required to keep it in solution and to increase tolerance. In order to achieve an adequate performance, GBCA must be administered in relatively large amounts. Chelate amounts are around 13-20 g and for Gd alone, this may amount to 3.3 g. Taking into account the route of administration, impurities in GBCA may be significant. Gadolinium occurs in nature along with 16 other elements known collectively as rare earth metals (RE), which are found throughout the earth's crust in minerals such as monazite. Gadolinium oxide corresponds to 0.7-4.0% of the RE present in minerals, and the sum concentration of RE in minerals is around 4%. Rare earth metals are difficult to separate, as the chemical and physical properties of one RE are significantly similar to those of others. In this study, the presence of other RE in GBCA formulations was investigated. Different lots of Magnevist®, Viewgam®, OptiMARK®, Omniscan®, Dotarem®, and Gadovist® were analyzed. Inductively-coupled plasma mass spectrometry and atomic absorption spectrometry were used for RE determination. Procedure optimization included sample decomposition and method validation for element determination. The results showed that Sc, Y, La, Ce, Pr, Nd, Eu, Tb, Tm, Dy, Ho, and Er were present in the 22 samples analyzed. Terbium, Thulium, Europium, and Lanthanum were, on average, found in the highest amounts, which were 0.42 mg/L, 0.17 mg/L, 0.17 mg/L, and 0.16 mg/L, respectively. These results could be attributed to the similarity among Europium, Gadolinium, and Terbium. They are in sequence in the periodic table and therefore present very close ionic radii, restricting their separation. Considering the sum of all RE, Viewgam® was the most contaminated formulation (mean of 2.16 mg/L) and Magnevist® the least (mean of 0.64 mg/L). Although the RE are chemically similar, the other RE do not perform as Gd as a contrast agent; therefore, their presence in formulations may be a matter of concern.

2.
Talanta ; 197: 20-27, 2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-30771924

RESUMO

New guidelines for the limits of elemental impurities in drug products were introduced by the International Council for Harmonization in 2014. While the guidelines define a limit for each element, the complete quantification of the 24 elements included is, in fact, unnecessary. An accurate "pass/fail" test to determine whether the threshold was exceeded or not could be valuable in this context. In this study, a screening procedure using the features of high-resolution continuum source graphite furnace atomic absorption spectrometry for the evaluation of 12 elements in three different drugs was developed. The three-dimensional absorbance spectrum including time and wavelength in the vicinity of the main line of the element allows for a pass/fail decision related to the presence or absence of the element in the sample. Additionally, the bi-dimensional absorbance-wavelength spectrum defines the elements captured in the window when additional peaks are seen in the spectrum. The analysis of the selected drugs included sample digestion, the definition of pyrolysis and atomization temperatures, determination of the limit of detection and other validation parameters for each element. The evaluation of the spectra, both three- and bi-dimensional, revealed that only three elements, Cr, Ni, and Cu, were present in the samples in amounts above the LOD and therefore "fail" in the test. Nevertheless, they were quantified, and the analysis revealed that their levels were below the permitted daily exposure, which are at least 6 times higher than the LOD of the selected elements. Operating in a routine mode, the proposed method is a good option for the evaluation of elemental impurities in drug active ingredients or drug final products.


Assuntos
Grafite/química , Losartan/química , Metais Pesados/análise , Omeprazol/química , Sinvastatina/química , Espectrofotometria Atômica
3.
PDA J Pharm Sci Technol ; 73(1): 60-69, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30232142

RESUMO

Flexible medical devices are primarily made of plasticized polyvinyl chloride (PVC). In recent times, to avoid undesired migration of the PVC plasticizers, ethyl vinyl acetate (EVA) and polypropylene (PP) has replaced PVC. Nevertheless, other additives are necessary to generate useful polymeric materials. Metallic species present in such additives can also leach out into the infusion solutions. The migration of barium (Ba), cadmium (Cd), lead (Pb), tin (Sn), and zinc (Zn) from devices made from PVC, EVA, and PP was evaluated. Bags and infusion sets were decomposed and their metallic contents analyzed. Glucose, NaCl, and Tween 80 were assessed as extraction media. These solutions were stored in PVC, EVA, and PP bags, heat-sterilized, and stored for 8 months at room temperature. Aliquots were taken before and after sterilization and then once per month to determine the contents of the metals. Commercial glucose and NaCl infusions were analyzed by taking aliquots of the solutions from the bags and from the administration set after their administration to patients. The three polymers contained the five metals. Ba was found in the highest concentration in all samples, with a mean of 8.0 mg/kg in PVC, 4.2 mg/kg in EVA, and 4.7 mg/kg in PP samples. Despite this, the only element that migrated into the glucose, NaCl, and Tween 80 solutions was Zn. The same result was found for the commercial glucose and NaCl infusions. Moreover, the Zn concentration in the administration sets was on average 52% higher than that found in the bags.LAY ABSTRACT: Flexible medical devices for infusions and artificial nutrition are made of plastics, such as polyvinyl chloride (PVC), ethyl vinyl acetate (EVA), and polypropylene (PP). These polymers contain additives necessary to generate useful materials. Metallic species present in these additives can leach out into the infusion solutions and come into contact with patients. To assess the risk of patient exposure to these metals, we evaluated the migration behavior of barium (Ba), cadmium (Cd), lead (Pb), tin (Sn), and zinc (Zn) from devices made from PVC, EVA, and PP. Bags and infusion sets were analyzed. Glucose, NaCl, and Tween 80 were investigated as extraction media. The three polymers contained the five metals. Ba was found in the highest concentration in all samples. Despite this, the only element that migrated into the glucose, NaCl, and Tween 80 solutions was Zn.


Assuntos
Embalagem de Medicamentos , Armazenamento de Medicamentos , Metais/química , Polímeros/química , Estabilidade de Medicamentos , Glucose/química , Infusões Intravenosas , Infusões Parenterais , Plastificantes/química , Polipropilenos/química , Polissorbatos/química , Cloreto de Polivinila/química , Cloreto de Sódio/química , Esterilização/métodos , Fatores de Tempo , Compostos de Vinila/química
4.
J AOAC Int ; 100(3): 737-743, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28105980

RESUMO

A sensitive and accurate method, employing high-resolution continuum source atomic absorption spectrometry, for the determination of antimony (Sb) was developed. Conditions such as pyrolysis and atomization temperatures, the use of chemical modifiers, and sample pretreatment were optimized for the determination of Sb in pharmaceutical preparations and beverages stored in polyethylene terephthalate (PET) containers. In addition to container analysis, the influence of time of contact, temperature, and content composition on the migration of Sb was investigated. Twenty-six samples were periodically analyzed until finalize 1 year bottling. Eight mineral water samples were analyzed after storage at temperatures from 40 to 80°C for 48 h. Five different-colored PET samples were stored at 80°C for 20 days and periodically analyzed. Bottles, containing from 46.4 mg/kg Sb (amber PET) to 91.6 mg/kg Sb (colorless PET), leached Sb depending on the content ingredients, time of contact, and temperature. Although drinking water itself did not promote Sb migration at room temperature, juices and medicines did. After 1 year of storage, the Sb level in the samples ranged from 5 to 50 µg/L. The rate of leaching depended on the temperature, which was slow below 60°C, but rapidly increased at 60-80°C. The higher the Sb content in the bottle, the higher the amount of migration. Because Sb is a possible carcinogen to humans, containers for pharmaceutical use should be better controlled, and factors that increase Sb leaching in products that are widely consumed should be avoided.


Assuntos
Antimônio/análise , Bebidas/análise , Preparações Farmacêuticas/análise , Espectrofotometria Atômica , Grafite
5.
Talanta ; 147: 241-5, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26592602

RESUMO

Nickel and cobalt were simultaneously assayed in vitamin B12 formulations by using atomic spectrometry. The proposed method is based on a compromise between the proximity of specific Ni and Co spectral lines and the relative abundances of the analytes in the samples. The analytes were found in concentrations ranging from 9.48 to 26.20µg L(-1) (Ni) and from 156.90 to 279.25mg L(-1) (Co) in the commercial samples of vitamin B12. The limits of detection and quantification were 1.21 and 3.64mg L(-1) for Co and 0.39 and 1.19µg L(-1) for Ni. Sample cleanup was not necessary for the determinations, and the interferences were discussed.


Assuntos
Cobalto/análise , Níquel/análise , Espectrofotometria Atômica/métodos , Vitamina B 12/química , Calibragem , Temperatura , Fatores de Tempo
6.
J Inorg Biochem ; 128: 215-20, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23916521

RESUMO

Aluminum (Al) delivered to preterm infants via parenteral nutrition may exceed the limit of 5 µg/kg/day set by the US Food and Drug Administration. This study evaluated the effect of the administration of an equivalent amount of Al (0.12 mg/kg/day) to newborn rats. The study included the administration of a higher amount of Al (24.8 mg/kg/day) not only to newborn rats but also to adult (2- and 4-month-old) rats. Aluminum was intraperitoneally administered for a period of 10 days. Newborn animals were evaluated for developmental changes every day starting from the second day after birth. Twenty days after the last administration, 10 animals were killed and their organs were removed; the remainders were killed on day 40. A dosage of 24.8 mg/kg/day was administered to the two groups of adult rats, which were killed following the same protocol after 20 and 40 days. The results of physical parameters and developmental and behavioral tests were not conclusive and no significant differences were observed between the lower and higher Al dose and control groups. The group that received 0.12 mg/kg/day showed significant differences in Al accumulation only in the liver and muscle. The groups that received a higher dose of Al showed an accumulation in all tissues among all age groups studied, but the newborn group showed the greatest accumulation (results for day 20). After 40 days, Al content in all tissues decreased more than 50% in this group, whereas among the adults, the Al content increased or remained constant. An increase in age correlated with a lower elimination rate. Considering the ongoing human Al exposure, along with its age-related elimination rate, Al accumulation in the body may be long-lasting.


Assuntos
Alumínio/farmacologia , Alumínio/farmacocinética , Reflexo/efeitos dos fármacos , Fatores Etários , Alumínio/administração & dosagem , Animais , Animais Recém-Nascidos , Encéfalo/metabolismo , Feminino , Humanos , Injeções Intraperitoneais , Rim/metabolismo , Fígado/metabolismo , Masculino , Músculos/metabolismo , Miocárdio/metabolismo , Distribuição Aleatória , Ratos , Ratos Wistar , Espectrofotometria Atômica , Fatores de Tempo , Distribuição Tecidual
7.
Ren Fail ; 35(3): 391-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23343454

RESUMO

BACKGROUND: Erythropoietin (EPO) formulations may comprise aluminum (Al) as a contaminant. Due to the toxicity of Al in chronic kidney disease patients, possible sources of Al were investigated. Since EPO formulations are stored in container-closure systems made of glass and rubber, and both contain Al, formulation ingredients may enable its leaching into the solution during shelf-life. METHODS: Individual solutions of formulation ingredients were stored in new glass vials and in contact with the rubber stopper and kept at 4 ± 2 °C. For 12 months, aliquots of each solution were collected for analysis. Fifteen commercial samples of EPO were analyzed for their Al content. Aluminum was determined by atomic absorption spectrometry. RESULTS: Glass and rubber are sources of Al for EPO formulations. Storage assay showed that citrate and phosphate (used as buffers) extracted high amounts of Al from the container/closure parts. The most important difference, however, was found when comparing liquid and lyophilized samples. While in liquid forms the Al level reached 943 µg/L, in lyophilized forms the level did not exceed 20 µg/L. The container system was also confirmed as a source of Al in reconstituted lyophilized samples. Al in reconstituted samples stored in their own vials increased 19-fold in 12 months. Lyophilized powders stored for 2 years in glass vials contained less Al than in 1 month after dissolution. CONCLUSION: The difference in the Al measured in liquid forms of EPO and in lyophilized powders suggests that the latter would be the best pharmaceutical form for CKD patients.


Assuntos
Alumínio/análise , Contaminação de Medicamentos , Embalagem de Medicamentos , Eritropoetina/química , Liofilização
SELEÇÃO DE REFERÊNCIAS